GDF46 Base Mount
Keep output and winding with the base configuration. The 1.5 kW and 2.2 kW assemblies have different lengths and currents; the two 2.2 kW PDFs are labeled by winding and remain specific to Base Mount.

HQD GDF SERIES
Select the fixing architecture and air-cooling installation before choosing a GDF by power. Base Mount and Housing Mount can share a printed code, while the round-body models change ER tooling, overall length and winding specification.
The listed GDF configurations are air cooled and use manual ER tooling. The range includes base fixing, housing support and round-body arrangements. Keep the mounting description with the complete code, then review the applicable air path with the enclosure and duty. A family name or ER designation cannot establish identical fixing surfaces or accessory hardware.
Keep output and winding with the base configuration. The 1.5 kW and 2.2 kW assemblies have different lengths and currents; the two 2.2 kW PDFs are labeled by winding and remain specific to Base Mount.
The 2.2 kW Housing Mount shares its printed code with Base Mount but requires its own support drawing. Equal power and overall length do not settle fixing interfaces, and base-specific PDFs do not establish housing applicability.
GDF65/0.8 and GDF80/1.5 use ER11; GDF80/2.2 uses ER16; /2.2B uses ER20 with its own 125 mm clamp region. Keep the suffix and exact outline when selecting a tool or adapting a bracket.
Include Base Mount or Housing Mount and compare the actual fixing drawing. The printed code is shared between those assemblies.
Review the applicable air path, bracket, guards, enclosure, duty and supplied service instructions. The motor rating does not specify a universal clearance or thermal setting.
The listed configurations include ER11, ER16 and ER20. Retain the complete code and B suffix before selecting accessories.
Rated points, curve conditions and electrical data apply to the exact supplied configuration. Compare the mounting datum, tool interface and selected winding with the installation drawing; equal series codes or power ratings alone do not establish interchangeability.
| Model / Configuration | Power / Duty | Speed | Tool Interface | Cooling | Diameter / Mounting | Selection Detail |
|---|---|---|---|---|---|---|
| GDF46-18Z/1.5 Base Mount | 1.5 kW rated | 18,000 rpm rated | ER20 | Air-cooled | Base Mount | Keep the 220 V / 5.6 A and 380 V / 3 A winding choices separate. |
| GDF46-18Z/2.2 Base mount | 2.2 kW rated | 18,000 rpm rated | ER20 | Air-cooled | Base mount | Include Base Mount with the shared GDF46-18Z/2.2 code in every drawing and quote request. |
| GDF46-18Z/2.2 Housing Mount | 2.2 kW rated | 18,000 rpm rated | ER20 | Air-cooled | Housing Mount | Keep Housing Mount with the shared printed code in drawing and quotation requests. |
| GDF65-24Z/0.8 | 0.8 kW rated | 24,000 rpm rated | ER11 | Air-cooled | Ø65 mm | Keep 220 V / 3 A and 380 V / 1.6 A as separate supplied winding choices. |
| GDF80-24Z/1.5 | 1.5 kW rated | 24,000 rpm rated | ER11 | Air-cooled | Ø80 mm | Keep 220 V / 5.6 A and 380 V / 3 A as complete separate winding pairs. |
| GDF80-24Z/2.2 | 2.2 kW rated | 24,000 rpm rated | ER16 | Air-cooled | Ø80 mm | Keep 220 V / 7.6 A and 380 V / 4.4 A as complete separate winding pairs. |
| GDF80-24Z/2.2B | 2.2 kW rated | 24,000 rpm rated | ER20 | Air-cooled | Ø80 mm | Keep the B suffix with the model so the ER16 non-B version is not substituted. |
ALL SPINDLES
Compare tooling, cooling and operating ratings, then open the exact configuration for your machine.
FILTER SPINDLES
Showing 7 configurations
Choose a winding voltage, not a voltage shown on a power curve. Ask us if the voltage you need is not listed.
Air-cooled spindle configurations with different housing and mounting arrangements. Match the interface, speed and installation drawing.

GDF · Manual
Base Mount
1.5 kW rated · ER20
18,000 rpm rated · Air-cooled
Base Mount · 258.5 mm overall
View specifications →
GDF · Manual
Base mount
2.2 kW rated · ER20
18,000 rpm rated · Air-cooled
Base mount · 288.5 mm overall
View specifications →
GDF · Manual
Housing Mount
2.2 kW rated · ER20
18,000 rpm rated · Air-cooled
Housing Mount · 288.5 mm overall
View specifications →
GDF · Manual
0.8 kW rated · ER11
24,000 rpm rated · Air-cooled
Ø65 mm · 245 mm overall
View specifications →
GDF · Manual
1.5 kW rated · ER11
24,000 rpm rated · Air-cooled
Ø80 mm · 256.5 mm overall
View specifications →
GDF · Manual
2.2 kW rated · ER16
24,000 rpm rated · Air-cooled
Ø80 mm · 263.5 mm overall
View specifications →
GDF · Manual
2.2 kW rated · ER20
24,000 rpm rated · Air-cooled
Ø80 mm · 269.5 mm overall · 125 mm clamp
View specifications →No matching configuration. Clear a filter or send us the details of your existing spindle.
INSTALLATION FIRST
CONFIGURATION & QUOTATION
Send the exact model with Base/Housing or B-suffix configuration, selected winding, fixing and enclosure evidence, drive model, quantity and destination. Include collets, accessories and winding-specific document needs.
A quotation requires the exact model and physical variant, selected winding, tooling, cooling requirements, quantity and destination. For a replacement, include the existing nameplate, mounting dimensions and equipment intended for reuse. CINKR confirms the proposed supply scope, availability and delivery terms by email.